Questions and answers of the customers
There are no questions yet. Be the first to ask a question about this product.
Detection
Mcp-red Ravel Make
₹ 516.84 GST included
Solo (330-001) Solo Aerosol Dispenser (HSN CODE 90318000)
₹ 31,860.00 GST included
Safe On Conventional Heat Detector
₹ 1,836.08 GST included
Solo 365 ES3 Smoke Detector Tester Cartridge(Pack of 12 Pcs)
₹ 64,546.00 GST included
Emergency & Exit Lights
Fire Extinguishers
Lightex DCP (BC) Stored Pressure Type Fire Extinguisher - 6 Kg
₹ 1,836.08 GST included
KalpEX 144B 4Kg MAP 75% BC Dry Chemical Powder Extinguisher
₹ 2,832.00 GST included
Safe On 22.5 Kg Co2 Type Fire Extinguisher
₹ 24,387.06 GST included
Sprinklers & Fire Fighting
Force F 1010 Gun Metal ISI Marked Branch Pipe Nozzel
₹ 3,932.94 GST included
Safenext Single Hydrant Valve Non 160 PCD
₹ 4,786.08 GST included
Force F 1010 Stainless Steel ISI Marked Branch Pipe Nozzel
₹ 2,752.94 GST included
ExoFire Short Branch Pipe SS (ISI) Wt-1.5kgs (MOQ - 3 Pcs)
₹ 1,246.08 GST included
Safety Gear
DARIT Finder Steel Toe Mid Sole Safety Work Boot, Anti-Slip Shock Absorption Oil Petrol Chemical Resistant Safety Shoes
₹ 2,360.00 GST included
DARIT VAULTEX Breathable Lining with Padded Collar Anti-Static Double Density PU Sole Steel Toe Cap and Steel MID Sole Plate Oil and Acid Resistant Safety Shoes
₹ 1,967.06 GST included
Kevlar 30" Aluminized Coat
₹ 12,744.00 GST included
Others
Honeywell IDP-MONITOR Address Monitor Module
₹ 2,083.88 GST included
Exide Power Safe Plus 12V 26AH SMF Battery
₹ 4,484.00 GST included
Swastik MS Flange 150mm (MOQ - 6 Pcs)
₹ 459.02 GST included
₹ 14,337.00 GST included
Smoke introduced into an air duct system will be distributed throughout the entire building. Smoke detectors designed for use in air duct systems are used to sense the presence of smoke in the duct. Model D4120 and D4S Duct Smoke Detectors utilize 4-wire photoelectric technology for the detection of smoke. This detection method, when combined with an efficient housing, samples air passing through the duct allowing detection of a developing hazardous condition. When sufficient smoke is sensed, an alarm signal is initiated and appropriate action can be taken to shut off fans, blowers, change over air handling systems, etc. These actions can facilitate the management of toxic smoke and fire gases throughout the areas served by the duct system. The D4120 and D4P120 detectors are designed to operate on 24 VDC/VAC or 120 VAC. Alarm and supervisory relay contacts are available for control panel
interface (alarm initiation), HVAC control, and other auxiliary functions. Auxiliary relays are provided for fan shut down. Detector interconnection provides signaling of up to 50 other detectors in the loop for multiple fan shut down.
These detectors are not designed for 2-wire applications.
X
There are no questions yet. Be the first to ask a question about this product.
Detections
Emergency Lights
Fire Extinguishers
Extinguisher Types
Sprinklers & Fire Fighting
Safety Gear
Safety Gear
Others
WirelessNo products in the cart.
Reviews
There are no reviews yet.