Questions and answers of the customers
There are no questions yet. Be the first to ask a question about this product.
Detection
Agni Smoke Detector
₹ 787.06 GST included
Agni Hunt AHSD-12 Optical Smoke Detector White
₹ 1,180.00 GST included
G-Tech Digital Earth Resistance Tester (2/3/4 Wire Test)
Honeywell DST1.5 Metal Sampling Tube For Duct Smoke Detectors
₹ 1,416.00 GST included
Emergency & Exit Lights
Fire Extinguishers
Safex Clean Agent 2 Kg Fire Extinguisher
₹ 14,750.00 GST included
Finish Fire RBC6 6kg DCP Fire Extinguishers Store Pressure With ISI Mark Type B
₹ 1,097.40 GST included
Kanex 2 KG Clean Agent Fire Extinguisher (HFC236fa Based Portable Stored Pressure)
₹ 11,669.02 GST included
Sprinklers & Fire Fighting
BFS Fire Hose Male Female SS Coupling (ISI) 202 Comercial Medium
₹ 2,516.94 GST included
ExoFire Round Clamp 20mm (MOQ - 30 Pcs)
₹ 92.04 GST included
Sangam Cast Iron Plus SS Double Hydrant - Compact -14Kg - Type-B, BOD-CI, BN-SS-202, AD-202
₹ 5,310.00 GST included
ArmorFire S.S 304 Single Hydrant Valve IS:5290 63mm, Type-A
₹ 6,962.00 GST included
Safety Gear
DARIT Finder Steel Toe Mid Sole Safety Work Boot, Anti-Slip Shock Absorption Oil Petrol Chemical Resistant Safety Shoes
₹ 2,360.00 GST included
DARIT VAULTEX Breathable Lining with Padded Collar Anti-Static Double Density PU Sole Steel Toe Cap and Steel MID Sole Plate Oil and Acid Resistant Safety Shoes
₹ 1,967.06 GST included
Kevlar 30" Aluminized Coat
₹ 4,956.00 GST included
Others
Exide EP200-12 Powersafe Plus Lead Acid Battery
₹ 22,125.00 GST included
Agni Hunt12 Zone Fire Alarm Panel
₹ 13,806.00 GST included
4 Zone Panel-ravel Make
₹ 11,977.00 GST included
₹ 42,598.00 GST included
Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 – 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network. 20 X 4 Dot Matrix LCD display. Alphanumeric keypads. RS 485 Communication for Network Repeater. System ON, AC ON, Battery ON, Charger ON indications. Lamp test facility. Maximum 16 panels including repeater can be connected in a Single Network via RS-485. Repeater Panel can monitor the status of RE-900 series panels via RS-485 Network communication. User can Disable / Enable the Zone of Fire Alarm Control Panel Connected in network. Ravel Indian Manufacturer, International standard. Operates on RS-485 communication. Repeats all the parameters of the main FACP.
RE-900 Series, Microprocessor based conventional Fire Alarm Control Panel, are designed to be used for medium and large size
commercial complexes and industrial establishments.This panel can accommodate a range of 12 zones upto 128 zones.User
friendly systems which involves a touch keypad to program the panel. This can be used as a standalone or networkable panel. Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 – 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network.