Questions and answers of the customers
There are no questions yet. Be the first to ask a question about this product.
Detection
Qutak QT BD2606 Beam Detector With 4 reflectors
₹ 19,470.00 GST included
Edward SIGA-OSD + SIGA-AB4G Addressable Smoke Detector with Sounder Base
₹ 4,838.00 GST included
G-Tech Digital Earth Resistance Tester (2/3/4 Wire Test)
Apollo SA5900-908APO Intelligent Manual Call Point
₹ 5,310.00 GST included
Emergency & Exit Lights
Fire Extinguishers
KalpEX 25Kg DCP SBC Type With Internal Cartridge
₹ 15,930.00 GST included
Ultra Fire M/FOAM Type (Stored Pressure) Fire Extinguisher -9 Ltr.
₹ 3,670.98 GST included
Safex ABC 2 Kg Fire Extinguisher stored pressure, MAP 40% (MOQ-2Pcs)
₹ 2,124.00 GST included
Sprinklers & Fire Fighting
RAINX Fire Hose Delivery Coupling - Aluminum Alloy (Male/Female)
₹ 1,010.08 GST included
Force F 1011 Two Way Fire Brigade Inlet Connection
₹ 5,243.92 GST included
RAINX Draw out connection
₹ 3,488.08 GST included
Zoloto Bronze Thermodynamic Steam Trap (Screwed) SS-304 Perforated Sheet Screen Ø0.5mm 15-25mm
₹ 4,981.96 – ₹ 11,733.92Price range: ₹ 4,981.96 through ₹ 11,733.92 GST included
Safety Gear
DARIT Finder Steel Toe Mid Sole Safety Work Boot, Anti-Slip Shock Absorption Oil Petrol Chemical Resistant Safety Shoes
₹ 2,360.00 GST included
DARIT VAULTEX Breathable Lining with Padded Collar Anti-Static Double Density PU Sole Steel Toe Cap and Steel MID Sole Plate Oil and Acid Resistant Safety Shoes
₹ 1,967.06 GST included
Kevlar 30" Aluminized Coat
₹ 12,744.00 GST included
Others
Exide EP200-12 Powersafe Plus Lead Acid Battery
₹ 22,125.00 GST included
Agni Hunt12 Zone Fire Alarm Panel
₹ 13,806.00 GST included
4 Zone Panel-ravel Make
₹ 11,977.00 GST included
₹ 42,598.00 GST included
Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 – 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network. 20 X 4 Dot Matrix LCD display. Alphanumeric keypads. RS 485 Communication for Network Repeater. System ON, AC ON, Battery ON, Charger ON indications. Lamp test facility. Maximum 16 panels including repeater can be connected in a Single Network via RS-485. Repeater Panel can monitor the status of RE-900 series panels via RS-485 Network communication. User can Disable / Enable the Zone of Fire Alarm Control Panel Connected in network. Ravel Indian Manufacturer, International standard. Operates on RS-485 communication. Repeats all the parameters of the main FACP.
RE-900 Series, Microprocessor based conventional Fire Alarm Control Panel, are designed to be used for medium and large size
commercial complexes and industrial establishments.This panel can accommodate a range of 12 zones upto 128 zones.User
friendly systems which involves a touch keypad to program the panel. This can be used as a standalone or networkable panel. Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 – 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network.
X
There are no questions yet. Be the first to ask a question about this product.
Detections
Emergency Lights
Fire Extinguishers
Extinguisher Types
Sprinklers & Fire Fighting
Safety Gear
Safety Gear
Others
Wireless
Reviews
There are no reviews yet.