Questions and answers of the customers
There are no questions yet. Be the first to ask a question about this product.
Detection
Crimscent Flame Proof PNG Gas Leak Detector-CI1100
₹ 17,700.00 GST included
Solo 423-001 Heat Detector Tester 110/120 Volt
GST included
TrueSafe TS230HLRB Residential LPG/PNG/CNG Gas Leak Detector
₹ 4,130.00 GST included
ExoFire Smoke/Heat Detector (MOQ - 4 Pcs)
₹ 687.94 GST included
Emergency & Exit Lights
Fire Extinguishers
Agni Hunt 1 Kg ABC Stored Pressure Type Fire Extinguisher
₹ 787.06 GST included
Lightex Clean Agent Fire extinguisher Modular Type - 15 Kg
₹ 32,252.94 GST included
Fipron Cord Type 3 Per Meter (MOQ 50 Meters)
₹ 20,060.00 GST included
Sprinklers & Fire Fighting
Force F 1017 Pendent 68 Degree Brass Fire Sprinklers
₹ 358.72 GST included
Swastik Foam Monitor 63mm (As Per Is) with FB5
₹ 21,240.00 GST included
Swastik Wafer check Valve Ductile Iron disk PN-10, Sizes: 100mm (MOQ - 2 Pcs)
₹ 1,377.06 GST included
ExoFire ABC Valve (MOQ - 10 Pcs)
₹ 261.96 GST included
Safety Gear
DARIT Finder Steel Toe Mid Sole Safety Work Boot, Anti-Slip Shock Absorption Oil Petrol Chemical Resistant Safety Shoes
₹ 2,360.00 GST included
DARIT VAULTEX Breathable Lining with Padded Collar Anti-Static Double Density PU Sole Steel Toe Cap and Steel MID Sole Plate Oil and Acid Resistant Safety Shoes
₹ 1,967.06 GST included
Kevlar 30" Aluminized Coat
₹ 4,956.00 GST included
Others
TOA Rigging Bracket, HY-TM7B-WP
₹ 42,952.00 GST included
TOA Infrared Wireless Receiver, IR-500R
₹ 17,228.00 GST included
TOA Matching Transformer for High-impedance Operation, MT-S0301
₹ 6,077.00 GST included
₹ 14,455.00 GST included
Switched Mode Power Supply. Modular Construction Auto Resettable Fuse Surge Protection for all Input and outputs. Programmable AC loss delay/Trouble Remainder/Alarm Verification Battery polarity reversible protection Surface Mount Technology Over All current consumption is low. Fully complies with UL -864 and NFPA-72. Rugged CRCA sheet with powder coated finish Operates on 110 220v 50 /60 Hz, AC Mains power supply. 16×2 Dot Matrix LCD Display. 4/8 Class B Style B or Style C initiating device circuit (IDC). All zones accept smoke detectors and any normally open contact device. Any Zone can be configured as Alarm or supervisory Zone. 2ClassBNotificationApplianceCircuits(NAC). NAC shall be programmed as silenceable or Non Silenceable. Supervisory Zone shall be Latching or Resettable. Standby (battery) backup 24v DC power supply with built in charger Error free Fire / Fault status in unambiguous colored LED indication. System ON indication. Main, Standby status audible and visual indication. Battery Low visual warning with audible tone. FormC relays for fire, fault and supervisory. Resettable / Steady 24V D.C. Output. RS 485 Communication facility (Optional). Lamp Test facility. All field wiring circuits are Power limited except 110 220v AC and Battery. All field wiring circuits are supervised. Walk Test facility. Zone Isolation facility with loop voltage cut off. Earth fault annunciation facility at 0 ohms. AC Low voltage cutoff. Programmable AC loss delay / Alarm verification / Trouble reminder.
The microprocessor based UL listed 8 Zone conventional fire alarm control panel, the system has 16 X 2 LCDcharacter, 8 zones detection circuit,3 common potential free contacts &2 common NAC sounder output, inbuilt Rs-485 for repeater connectivity, wall/ceiling mounted, Switch mode power supply- SMPS & Battery polarity & Deep discharge protection. RE-2558 fire alarm control panel is designed with unique protocol to be used for small & medium establishments, Schools, hospitals, hotels, banks, residential / commercial building, and small scale industries. The system is user friendly with includes all standard to ensure ease for use and high reliability. Switched Mode Power Supply. Modular Construction Auto Resettable Fuse Surge Protection for all Input and outputs. Programmable AC loss delay/Trouble Remainder/Alarm Verification Battery polarity reversible protection Surface Mount Technology Over All current consumption is low. Fully complies with UL -864 and NFPA-72. Rugged CRCA sheet with powder coated finish Operates on 110 220v 50 /60 Hz, AC Mains power supply. 16×2 Dot Matrix LCD Display. 4/8 Class B Style B or Style C initiating device circuit (IDC). All zones accept smoke detectors and any normally open contact device. Any Zone can be configured as Alarm or supervisory Zone. 2ClassBNotificationApplianceCircuits(NAC). NAC shall be programmed as silenceable or Non Silenceable. Supervisory Zone shall be Latching or Resettable. Standby (battery) backup 24v DC power supply with built in charger Error free Fire / Fault status in unambiguous colored LED indication. System ON indication. Main, Standby status audible and visual indication. Battery Low visual warning with audible tone. FormC relays for fire, fault and supervisory. Resettable / Steady 24V D.C. Output. RS 485 Communication facility (Optional). Lamp Test facility. All field wiring circuits are Power limited except 110 220v AC and Battery. All field wiring circuits are supervised. Walk Test facility. Zone Isolation facility with loop voltage cut off. Earth fault annunciation facility at 0 ohms. AC Low voltage cutoff. Programmable AC loss delay / Alarm verification / Trouble reminder.
X
There are no questions yet. Be the first to ask a question about this product.
Detections
Emergency Lights
Fire Extinguishers
Extinguisher Types
Sprinklers & Fire Fighting
Safety Gear
Safety Gear
Others
Wireless
Reviews
There are no reviews yet.