Questions and answers of the customers
There are no questions yet. Be the first to ask a question about this product.
Detection
Ravel RE-428DU-S Addressable Duct Detector with Sampling tube length: 2 ft (0.6 m)
₹ 19,706.00 GST included
BW Max XT II Multi Gas Detector
₹ 63,720.00 GST included
Watchgas SST1 Single Gas Detector
₹ 24,337.50 GST included
ASES Photo Thermal Multi Criteria detector with base. Model No. AS-607-PTH
₹ 1,003.00 GST included
Emergency & Exit Lights
Fire Extinguishers
Excellent CO2 22Kg Type Fire Extinguisher For Outdoor
₹ 30,326.00 GST included
Swastik Water Type Fire Extinguisher - 9 ltrs (MOQ - 2 Pcs)
₹ 2,490.98 GST included
Excellent 4Kg Clean Agent Fire Extinguisher For Outdoor
₹ 19,352.00 GST included
Sprinklers & Fire Fighting
Agni Hunt Star Pendant Make Fire Sprinkler
₹ 328.04 GST included
Swastik Dual plate wafer check Valve Ductile Iron disk PN-10, Sizes: 40mm (MOQ - 4 Pcs)
₹ 720.98 GST included
NVR C.I Dual Plate Check Valve PN-1.6, Door-SS (CF-8), Hinge Pin-SS304, Seat-Nitrile or EPDM Rubber, SS Spring 50 - 300mm
₹ 3,606.08 – ₹ 65,882.94Price range: ₹ 3,606.08 through ₹ 65,882.94 GST included
Swastik 2-Way Inlet Breeching, Cast Iron body having 2 Gun Metal, 63mm Male Instantaneous inlets, fitted with Non-return valves, complete with Gun Metal drain valves, 2 Rubber blank caps and Chain.
₹ 6,228.04 GST included
Safety Gear
DARIT Finder Steel Toe Mid Sole Safety Work Boot, Anti-Slip Shock Absorption Oil Petrol Chemical Resistant Safety Shoes
₹ 2,360.00 GST included
DARIT VAULTEX Breathable Lining with Padded Collar Anti-Static Double Density PU Sole Steel Toe Cap and Steel MID Sole Plate Oil and Acid Resistant Safety Shoes
₹ 1,967.06 GST included
Kevlar 30" Aluminized Coat
₹ 4,956.00 GST included
Others
Honeywell IDP-MONITOR Address Monitor Module
₹ 2,083.88 GST included
Exide Power Safe Plus 12V 26AH SMF Battery
₹ 4,484.00 GST included
Swastik MS Flange 150mm (MOQ - 6 Pcs)
₹ 459.02 GST included
₹ 71,862.00 GST included
Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 – 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network. 20 X 4 Dot Matrix LCD display. Alphanumeric keypads. RS 485 Communication for Network Repeater. System ON, AC ON, Battery ON, Charger ON indications. Lamp test facility. Maximum 16 panels including repeater can be connected in a Single Network.
RE-900 Series, Microprocessor based conventional Fire Alarm Control Panel, are designed to be used for medium and large size commercial complexes and industrial establishments. This panel can accommodate a range of 12 zones upto 128 zones. User friendly systems which involves a touch keypad to program the panel. This can be used as a standalone or networkable panel. Complies with UL -864 and NEPA -72. 20 x 4 dot matrix LCD display. Operates on 120 – 220VAC 60 /50 Hz, AC mains power supply. Standby (battery) backup 24 VDC power supply with built in charger. Touch keypad for user friendly operation. Epoxy powder coated finish. Class- B, Style B / C initiating device circuit (IDC). All zones accept smoke detectors and normal open contact devices. Class B notification appliance circuits (NAC). NAC shall be programmed as AUTO SILENCE / Silence Inhibit. Error free Fire / Fault status in unambiguous colored LED indication. 1000 Event storage with RTC. Main, Standby status with audible and visual indication. Two Form C relays for fire and fault. Resettable / Steady 24VDC. Output. RS 485 Communication facility. TCP/IP facility (Optional) MODBUS for Building Management System integration (Optional). PC software (optional) External zone wise sounder/contact via RS 485 (Optional). All field wiring circuits are supervised. Zone Isolation facility with loop voltage cut off. Zones available : 12, 16, 20, 24, 32, 48, 64,96 and 128. Facility to connect Public Address System (PA) through RS-485 Comm Peer to Peer network facility. Maximum 16 panels can be connected to a single network. 20 X 4 Dot Matrix LCD display. Alphanumeric keypads. RS 485 Communication for Network Repeater. System ON, AC ON, Battery ON, Charger ON indications. Lamp test facility. Maximum 16 panels including repeater can be connected in a Single Network.
X
There are no questions yet. Be the first to ask a question about this product.
Detections
Emergency Lights
Fire Extinguishers
Extinguisher Types
Sprinklers & Fire Fighting
Safety Gear
Safety Gear
Others
Wireless
Reviews
There are no reviews yet.