TOA Voice Evacuation Frame, VX-3016F
Up to 2 amps (16 switched zones plus Standby amp or 2 x 8 Switched Zones). All Mandatory Indications by EN54-16. Status Indication for each Speaker Line. Fault Acknowledge and Lamp test Button. Input DSP: Flexible filtertypes and Compressor. Output DSP: Flexible filtertypes, compressor and delay up to 2.7 sec.
TOA Line Output Module, VX-300LO
Line Output Module to be mounted in the VX-3000 frame. Outputs audio signals at the line level from the VX-3000 Frame to an external device.
TOA Voice Evacuation Frame, VX-3008F
Up to 3 amps (8 zones Switching between 2 amps plus standby amp or 8 zones freely assignable to 1 of 2 amps). All Mandatory Indications by EN54-16. Status Indication for each Speaker Line. Fault Acknowledge and Lamp test Button. Input DSP: Flexible filtertypes and Compressor. Output DSP: Flexible filtertypes, compressor and delay up to 2.7 sec.
TOA Voice Evacuation Frame, VX-3004F
Up to 4 amps (1 zone - 1 amp, 4 AB-zones or 3 AB zones plus standby amp). All Mandatory Indications by EN54-16. Status Indication for each Speaker Line. Fault Acknowledge and Lamp test Button. Input DSP: Flexible filtertypes and Compressor. Output DSP: Flexible filtertypes, compressor and delay up to 2.7 sec.
TOA Preamp Matrix Panel, VX-3000PM
Preamplifier Matrix panel enabling the additional Audio Inputs, Control Inputs and Control Outputs to the VX-3000 system. Equipped with 8 Audio inputs with Volume controls, 20control inputs and 10 control outputs. Provides Unicast Audio Streaming Functionality. Unicast audio streaming is possible among VX-3000PMs. 1 unit can be Connected to a Single VX-3000 Frame and a maximum of 40 units can be configured per system.
TOA Power Supply Manager, VX-3000DS
Emergency Power Supply Manager used for the VX-3000 systems. Equipped with a Battery Charger and Dual Switching power Supplies. Energy-saving and Lightweight Design. Easy Maintenance.
TOA Control Panel, VX-3000CT
Designed for Exclusive use with the VX-3000 Series Evacuation System. Equipped with 9 Function Keys and 8 Volume Controls. Up to 2 Units can be Connected to a single VX-3000 Frame. Maximum of 80 units can be Configured per System. Can be Mounted in a EIA equipment Rack (1U size).
TOA Power Supply, VX-200PS
Power Supply Unit. 2 DC output channels per Unit. EN 54-4 certified, Certificate No: 1134-CPR-083.
TOA Power Supply, VX-2000PF
Frame for Rack Mounting of up to 3 VX-200PS Power Supply Units. EN 54-16 certified, Certificate No: 1134-CPR-110.
TOA Emergency Power Supply, VX-2000DS
Up to 3 (6 ch) VX-200PS Power Supply Units can be connected per VX-2000DS to supply backup DC power to Individual Components. Automatically Switches to the backup power supply when the DC power supply from the VX-200PS is Interrupted. Detects charging circuitry or Battery failures, and Transmits Failure Signals to the DS LINK of the TOA Voice. Evacuation Systems (VX-2000, SX-2000, and VM-3000). Keeps a 2 x 12 V Sealed lead-acid Battery charged while Maintaining Temperature compensation for the charging Voltage. Automatically disconnects the battery if its voltage reaches a discharge final level.
TOA Power Amplifier Module, VX-1500DA-AS
Class D power amplifier module. Mounts in the Frame Units. Dust filter, Easy to Clean.
TOA Power Amplifier Module, VX-1250DA-AS
Class D power amplifier module. Mounts in the Frame Units. Dust filter, Easy to Clean.
TOA Zone Expansion Panel, VX-1010ZE-AS
Control up to 10 speaker zones. Up to 16 VX-1010ZE can be used in a System. Supports 10 control inputs plus 1 emergency control input. Supports detection functions such as speaker line surveillance, power amplifier fault detection based on VX-1000MC.
TOA IP Remote Microphone, VX-100RM-EA
For TOA VX-1000 System. Initiates General and Emergency Broadcasting. Triggers Pattern Broadcast Task by Pressing the Key. Remote Microphone Extension (RM-110VX) Unit can be Connected to it. Each Extension Unit has 10 keys. Can Add up to 9 units of RM-110VX to Achieve a Total of 100 Function Keys.
TOA Peering Frame, VX-1000PF
Supplies Power to the Power Amplifier Module inserted in it. Displays Operation and Fault Status of the Power Amplifier Module. Supports Redundancy for power supply. If Power supply A Fails, Automatically switch to Power supply B. When Power supply A Returns to Normal, it will Automatically return to Power supply A. Standard 4U rack-mounted design.
TOA Matrix Controller, VX-1000MC-AS
Hard Buttons and Knobs for easy Broadcast operations. 4.3 inch LCD screen displays operation information, fault information, equipment Information. ANC Noise Detection Function. Equipment and Speaker line have Fault Detection.
TOA System Amplifier, VX-050DA
Low loss Modular Class-D Amplifier. Modules to be Mounted in the Frame Units. Power level: 150 W. Can Easily be Removed or Replaced simply by Unplugging them, no need for Special Tools. Dust filter, easy to clean. 100 V Output without transformer resulting in light-weight units. Fuse easily accessible from rear.
TOA System Amplifier, VX-030DA
Low loss Modular Class-D Amplifier. Modules to be Mounted in the Frame Units. Power level: 150 W. Can Easily be Removed or Replaced simply by Unplugging them, no need for Special Tools. Dust filter, easy to clean. 100 V Output without transformer resulting in light-weight units. Fuse easily accessible from rear.
TOA System Amplifier, VX-015DA
Low loss Modular Class-D Amplifier. Modules to be Mounted in the Frame Units. Power level: 150 W. Can Easily be Removed or Replaced simply by Unplugging them, no need for Special Tools. Dust filter, easy to clean. 100 V Output without transformer resulting in light-weight units. Fuse easily accessible from rear.
TOA System Management Amplifier, VM-3360VA
Master, 1 Unit per System. 360 W Power Output. 8 Remote Microphones (4x general, 4x emergency). EN54: max. 2 x emergency or 4 x general plus 1 x emergency). 6 Zones, for BGM selectable with volume control from the Front Panel. Built-in High Quality Electronic voice store for 2 emergency and 6 general messages.