GST Conventional Ultraviolet Flame Detector, C-9104 + DZ-03

 12,095.00
Ultraviolet Sensor that Detects the UV rays emitted by a Flame. Aesthetically pleasing low Profile Design. Dust-proof, Damp-proof and Corrosion-proof.
Add to cart

GST GMC Graphic Monitor Center, GST-GMC3.0

 95,875.00
Color Graphic Control and Display System. Providing a Complete Window on the Fire Detection Systems and Ancillary Equipment. One Local Operator and Maximum 8 Remote users. Multi-level Password Control for Convenient System management. PC not Included.
Add to cart

GST Digital Zone Monitor Module, DI-9319E

 4,720.00
Cable checking for Inputs and Outputs. Normally-open (NO) or Normally-close (NC) output Automatically follows Input Port to Change State. Electronically addressing. Addresses can be Modified in field. DIN-Rail Mounted or Wall mounted. Standard: EN 54-18:2005.
Add to cart

GST Addressable Sounder, I-9404

 4,248.00
Providing 16 tones. Loop Powered or External 24V Powered. Power-saving Consumption Mode and Normal consumption mode (factory default). Single/ Dual address Programmable. Standard: EN 54-3.
Add to cart

GST Addressable Reflective Beam Detector, DI-9105E

 29,500.00
Loop Powered. Optical Pathway 5-100 Mtrs. Combination of the Emitting and Receiving part Makes mounting easy and optical pathway accurate. Built-in Microprocessor Enables intelligent judgment about fire alarm and fault. East alignment and commisioning via supporting of onboard laser pointer and digital signal intensity indication. Self-diagnostic function can monitor the internal fault. Electronically addressed by programmer. Four sensitivity levels can be set in field. LPCB Approved.
Add to cart

GST Passive Remote Indicator, C-9314P (MOQ-4Pcs)

 708.00
LED Indication Available. Built-in Current-limiting Resistor. Controlled by a Detector.
Add to cart

GST Isolator Base, DC-9504E (MOQ-2Pcs)

 1,357.00
Polarity-sensitive External Connections. Input and Output can be used Inversely without Direction. Delayed Power-up to Output end Devices. Avoids strong Transient Current the Load is Heavy. Applicable to all kinds of Loop Fire Alarm Systems. Suitable for A and Class B.
Add to cart

GST Intelligent Rate of Rise and Fixed Temperature Heat Detector, DI-9103E (MOQ-2Pcs)

 1,947.00
Designed to Comply with EN 54-5 Standard. Remote Indicator output available. Electronically Addressed in field. Polling LED can be set to close. Fire LED allows 360 Deg. Viewing. 3 classes Programmable. Reed switch Testing. Self-diagnostic.
Add to cart

GST Hand Held Programmer – Latest version, P-9920

 15,694.00
Hand held Unit, Small Size. Easy to Carry and Operate. Register On-line Devices. Identify Device Type and Report Repeat Address on same Loop. Test Device functionality. Set and Read Device's Address and Sensitivity. Adopt 128 x 128 Dot Matrix LCD Screen with Backlight Display. Low Power Consumption mode, automatic shutdown. Low Battery Indication.
Add to cart

GST Hand Held Programmer, P-9910B

 13,570.00
Hand held Unit, Portable Tool. Convenience Operation. Quadruple Digit Alphanumeric LCD Display. Low-consumption Hibernation and Power Saving Function. E-Low Battery Indication. WEEE & RoHS Compliant.
Add to cart

GST Loop Relay Module, P-9903

 15,694.00
Digital Communication with Fire Alarm Control Panel (FACP) ensures Immunity to Electromagnetic Interference and Reliable Operation. Optoisolated Output Signal, resistant to Industrial Frequency Interference. Optocoupler Isolation Technology is used between the Transmitter and Receiver Circuit.
Add to cart

GST ModBus Communication Card for IFP8 panel, P-9935ModBus

 19,116.00
Complying with Modbus RTU Communication Protocol. Standard RS232 interface, used for System Integration of the Third Party. Card Shouldn’t be Inserted and Removed when it is Energized. Default DIP Code is 6.
Add to cart

GST Class A RS485 Network Card for IFP8 panel, P-9945A

 15,222.00
Two Photoelectric Isolation RS485 Interfaces. Suitable for Ring Network. Card Shouldn’t be Inserted and Removed when it is Energized.
Add to cart

GST Communication Card for IPF8 panel, P-9935

 12,921.00
Complying with Modbus RTU Communication Protocol. Standard RS232 interface, used for System Integration of the Third Party. Card Shouldn’t be Inserted and Removed when it is Energized.
Add to cart

GST Dual Loop Card for IFP8 Panel, LCIFP8

 38,350.00
Dual Loop Card. System Expansion Card. Adds Two Additional Loops.
Add to cart

GST ModBus Communication Card for GST200N panel, P-9930ModBus

 19,116.00
Comply with Modbus RTU Communication Protocol. Standard RS232 Interface, used for System Integration of the Third party. Card Shouldn’t be Inserted and Removed when it is Energized.
Add to cart

GST Class A RS485 Network Card for GST200N panel & NRP00 Repeater Panel, P-9940A

 12,921.00
Two Photoelectric Isolation RS485 Interfaces. Suitable for Ring Network. Card Shouldn’t be Inserted and Removed when it is Energized.
Add to cart

GST Communication Card for GST200N Panel, P-9930

 9,617.00
Standard RS232 and USB interfaces. Connecting GST Graphic Monitor Center and GST Defining Tool. Card Shouldn’t be Inserted and Removed when it is Energized.
Add to cart

GST Single Loop Card for GST200N panel, LC200

 22,302.00
Connecting with Loop Devices. Add one Loop to connect 242 Addressable Devices. Card Shouldn’t be Inserted and Removed when it is Energized.
Add to cart

GST Intelligent Fire Alarm Control Panel, GST200N-1

 55,991.00
Max. 30 Zones. Each zone has its own Alarm and Fault/ Disable Indicator and a Label. Single Loop panel capacity 235 Addressable Devices. 2-loop Panel capacity 477 Addressable Devices. Compatible with GST Intelligent and Digital products. 8X18 Characters LCD screen. 15 LEDs to Display Important Information. Non-Volatile memory ensures No loss of Data even if Power supply is Accidentally Removed. Wide range Power Supply. Sounder Strobe output provides 0.5A24V Load, Compatible with GST Conventional Sounders. RS232 Interface enables Communication with PC.